Chattanooga Intelect

Chattanooga Intelect TranSport Combo

The Chattanooga Intelect TranSport Combo is a portable combination unit for electrotherapy and therapeutic ultrasound, with two stimulation channels and a dual-frequency ultrasound generator in one case. Interferential, Premodulated, High Voltage Pulsed Current and Russian waveforms cover the stimulation side, each running 1 to 60 minutes. The ultrasound side works at 1 MHz or 3.3 MHz through four interchangeable head sizes, reaching 20 W at 1 MHz on the 10 cm2 head. One case covers both modalities, so a single bench or cart serves the stimulation and ultrasound work in a room. It runs from mains or a NiMH pack, and the 5 cm2 head ships with it.

The unit weighs 2.3 kg with its base. The Transportable NiMH pack of twenty AA cells weighs 0.85 kg and drops into the base in place of the mains lead.

Stimulation
2 channels
Independent intensity
Waveforms
4 on board
IF, premod, HVPC, Russian
Ultrasound
0-20 W
10 cm2 head at 1 MHz
Protocol memory
15 positions
User defined
1 and 3.3 MHz ultrasound Four interchangeable head sizes 100-240 V mains or NiMH pack 5 cm2 head included

Output and control

How it works

A combination unit has two output sides to judge: the stimulation front end, scaled in milliamps and volts, and the ultrasound generator, scaled in watts and set by the head you fit.

Waveforms Set in mA and Volts
Interferential runs 0-100 mA with a 2000-5000 Hz carrier and a 1-200 Hz beat, in constant current or constant voltage. Premodulated is 0-100 mA on a fixed 2500 Hz carrier. High Voltage Pulsed Current is 0-500 V at 10-120 pps, a twin-peak pulse. Russian is 0-100 mA at 20-100 bps with duty cycles of 10, 20, 30, 40 and 50 percent, and all four waveforms run 1-60 min.
0-500 V peak
Dual-Frequency Ultrasound
1 MHz and 3.3 MHz, a collimating beam and a beam nonuniformity ratio of 5.0:1 or less. Output power is head-dependent: 0-2 W on the 1 cm2, 0-4 W on the 2 cm2, 0-10 W on the 5 cm2, and 0-20 W at 1 MHz or 0-10 W at 3.3 MHz on the 10 cm2. Intensity is 0-2.5 W/cm2 continuous and 0-3 W/cm2 pulsed, across duty cycles of 10, 20, 50 and 100 percent.
1 and 3.3 MHz
Effective Radiating Area by Head
Four sound head sizes, each pre-calibrated and interchangeable on the same base. Effective radiating area is 0.7-1 cm2 on the 1 cm2 head, 1.4-2 cm2 on the 2 cm2, 3.5-5 cm2 on the 5 cm2 and 6.8-10 cm2 on the 10 cm2. The 5 cm2 head is the standard applicator that ships with the unit, and the other three sizes are separate orders that move the output ceiling with them.
4 head sizes
Applied Parts in a CLASS I Case
Mains input is 100-240 V, 1.0 A, 50/60 Hz, 100 W max, with a +24 V, 3.125 A internal rail. Electrical class is CLASS I, with TYPE B applied parts for ultrasound and TYPE BF for electrotherapy. Safety standards behind the unit are UL/IEC/EN 60601-1, IEC/EN 60601-1-2 and IEC 60601-2-10.
100-240 V

Ownership

Key features

The TranSport Combo runs on mains or battery, goes through electrodes and coupling gel, and docks to a therapy cart through one adapter.

Weight and case size
2.3 kg with its base, light enough to carry between treatment rooms.
User protocol memory
The operator enters waveform and parameters on the keypad and saves the setup to one of fifteen user-defined positions, so a treatment a room runs daily is recalled in a few presses.
Channels set separately
Each of the two channels takes its own intensity and parameter entry on the keypad.
Interchangeable heads
The four sound head sizes swap on the same base, and each one moves the output ceiling with it.

The family

How it compares

The TranSport Combo, TranSport Ultrasound and TranSport 2-Channel make up the first-generation TranSport family, and they differ in stimulation channels, ultrasound output and protocol memory.

Chattanooga Intelect TranSport Ultrasound
TranSport Ultrasound
First-generation ultrasound only, rated for 2 to 5 hours of battery treatment time.
Stimulation channels: 0, ultrasound only ERA, 5 cm2 head: 3.5 to 5 cm2 Battery runtime: 2 to 5 hours of treatment Mains input: 120 to 240 V, 50/60 Hz, 75 VA
Shop the TranSport Ultrasound
You're Here
Chattanooga Intelect TranSport Combo, portable combo unit
TranSport Combo
First-generation combo, with four waveforms in milliamps and 0 to 20 W ultrasound.
Stimulation channels: 2 Interferential: 0 to 100 mA, carrier 2000 to 5000 Hz 10 cm2 head: 0 to 20 W at 1 MHz User protocol memory: 15 positions
Currently viewing
Chattanooga Intelect TranSport 2-Channel Electrotherapy unit
TranSport 2-Channel
First-generation stimulation only, carrying four waveforms with output set in volts.
Stimulation channels: 2 Interferential: 0 to 100 V, carrier 2000 to 10,000 Hz High Voltage Pulsed Current: 0 to 500 V, 10 to 120 pps User protocol memory: 10 positions
Shop the TranSport 2-Channel

Questions

Frequently asked questions

No. This is the first-generation Intelect TranSport Combo. The Intelect Transport 2 Combo is the later generation, on a different chassis with a different applicator series, and no applicator, battery, carry bag or cart adapter crosses between the two.

The first-generation Intelect series, in 1 cm2, 2 cm2, 5 cm2 and 10 cm2, sold as Intelect ultrasound applicators. The 5 cm2 head ships with the unit.

No. The 1 cm2 head runs at 3.3 MHz only. For a 1 MHz protocol, fit the 2, 5 or 10 cm2 head, and the full 0-20 W comes on the 10 cm2 head at 1 MHz.

100-240 V, 1.0 A, 50/60 Hz, 100 W max. The range is wide enough to run the unit outside North America without a transformer. Off mains, the Transportable NiMH pack of twenty AA cells at 1.2 V seats in the base.

The stimulation waveform and its parameters, the intensity on each of the two channels, and on the ultrasound side the applicator size and the 1 MHz or 3.3 MHz generator, all on the keypad against a graphical LCD. Duty cycles run 10, 20, 50 and 100 percent, and ultrasound stops at 30 minutes.

The device is contraindicated over cancerous lesions and open wounds, during pregnancy and over a pregnant uterus, and in patients with cardiac demand pacemakers. Stimulation should not be applied transthoracically, because current of this magnitude must not flow through the thorax and may cause a cardiac arrhythmia, and stimulation should not be applied over the anterior neck. Read the complete list in the manual before first use.

Two matter on every ultrasound treatment: always keep the sound head in constant motion and always keep the sound head in full contact with the patient's skin. Patients with implanted neurostimulation devices must avoid diathermy. On the stimulation side, current of this magnitude must not flow through the thorax.

The Combo is the only one of the three first-generation TranSport units that carries both modalities. The TranSport Ultrasound is ultrasound only, and the TranSport 2-Channel is stimulation only, scaling its output in volts where the Combo scales in milliamps. All three share the NiMH battery pack, the carry bag and the grey cart adapter.

The 5 cm2 applicator, a leadwire for each of channels 1 and 2, electrodes, coupling gel and the manual on CD. The NiMH pack, the Intelect TranSport carry bag and the cart adapter are sold separately, and the electrode reorder is Dura-Stick Plus self-adhesive electrodes.

Yes. The grey TranSport cart adapter, sold separately, docks the Combo to the Vectra Genisys therapy cart.

  • Interferential output: 0-100 mA, carrier 2000-5000 Hz, beat 1-200 Hz, CC or CV
  • Premodulated output: 0-100 mA, carrier 2500 Hz, beat 1-200 Hz
  • High Voltage Pulsed Current: 0-500 V, 10-120 pps, twin-peak pulse
  • Russian output: 0-100 mA, 20-100 bps, duty cycle 10/20/30/40/50%
  • Stimulation treatment time: 1-60 min, all waveforms
  • Ultrasound output power: 0-2 W (1 cm2), 0-4 W (2 cm2), 0-10 W (5 cm2), 0-20 W at 1 MHz (10 cm2)
  • Ultrasound intensity: 0-2.5 W/cm2 continuous, 0-3 W/cm2 pulsed
  • Effective radiating area: 0.7-1 / 1.4-2 / 3.5-5 / 6.8-10 cm2 by head size
  • Beam nonuniformity ratio: 5.0:1 or less
  • Beam type: Collimating
  • Maximum ultrasound treatment time: 30 minutes
  • Dimensions: 29.2 x 25.7 x 18.4 cm (L x W x H)
  • Weight: 2.3 kg with base; battery pack adds 0.85 kg
  • Mains input: 100-240 V, 1.0 A, 50/60 Hz, 100 W max
  • Electrical classification: CLASS I; TYPE B ultrasound, TYPE BF electrotherapy
  • Safety standards: UL/IEC/EN 60601-1, IEC/EN 60601-1-2, IEC 60601-2-10
  • Model: 2738, first-generation Intelect TranSport Combo
  • Generation note: Not the Intelect Transport 2 Combo (4738); applicators, batteries, carry bags and cart adapters do not cross
  • Stimulation channels: Two, with independent intensity and parameter control
  • Waveforms on board: Interferential, Premodulated, High Voltage Pulsed Current, Russian
  • Ultrasound frequencies: 1 MHz and 3.3 MHz, selectable
  • Sound head sizes: 1, 2, 5 and 10 cm2, interchangeable; 5 cm2 (27383) standard
  • 1 cm2 head limitation: 3.3 MHz only; the 2, 5 and 10 cm2 heads run both frequencies
  • Ultrasound duty cycles: 10%, 20%, 50% and continuous (100%)
  • User protocol memory: 15 user-defined positions
  • Display: Graphical LCD with keypad parameter entry
  • Power options: Mains, or NiMH battery pack 27478 (20 x AA)
  • Cart mounting: Docks to the Vectra Genisys cart (2775) via the 2884 adapter
  • Consumables: Self-adhesive electrodes and ultrasound coupling gel
  • Intended setting: Clinic treatment room; bench unit or cart-docked, operated by trained staff
  • Unit: Intelect TranSport Combo
  • Ultrasound applicator: 5 cm2 head, part 27383
  • Leadwires: One each for channels 1 and 2
  • Electrodes: Electrodes for the stimulation channels
  • Gel: Coupling gel
  • Documentation: Manual on CD
  • Battery: Not included; NiMH pack 27478 sold separately
  • Cart adapter: Not included; grey adapter 2884 sold separately