Chattanooga Triton Traction Unit

Original price $4,881.00 - Original price $4,881.00
Original price
$4,881.00
$4,881.00 - $4,881.00
Current price $4,881.00

✓ Authorized Chattanooga Dealer
✓ Lowest Price Guaranteed
✓ FREE & FAST Shipping: In Stock and Ready to Ship
✓ Questions? Call an RFA Team Member: 1-855-864-6442

10% Off Fall Sale with Code: CHATT10

Chattanooga Triton

Chattanooga Triton Traction Unit

The Chattanooga Triton Traction Unit is a programmable benchtop traction unit for cervical and lumbar work, built to mimic hands-on therapy. A load cell holds the pull at the figure you program, anywhere from 0 to 200 lb (0 to 90 kg) in 1 lb steps. Pretension, progression, traction and regression each run on independent timers, across static, intermittent and cyclic modes. Programmable pretension eases the patient in and helps reduce muscle guarding. Up to 80 protocols sit behind a color touch screen, and the head mounts to a Triton or Galaxy traction table.

Each protocol times its own pull: 1 to 99 minutes of traction in 1 minute steps, hold and rest of 0 to 99 seconds each in 1 second steps, and 1 to 9 progressive and regressive steps. One protocol can ramp the pull on, hold it, ease it off and hold again without a clinician touching the console.

The head measures 9.5 x 17.5 x 17.5 in. (24 x 45 x 45 cm) and weighs 30 lb (14 kg), 40 lb (18 kg) in its shipping carton. Mains input is 100 V to 240 V at 50/60 Hz, 75 VA, 3.2 A max, Class I, Type B, rated for continuous operation, and the same head runs on a 120 V clinic outlet and on a 230 V supply without a transformer.

It is the head on its own: the table, belting and cervical device are sold separately, and the DTS software comes only in the 2841 head. The Triton DTS Traction Unit with sEMG comes inside the Basic and Advanced accessory packages.

Traction tension
0-200 lb
1 lb increments
Protocol storage
80 protocols
User-defined
Display
Color touch screen
270 deg pivot
Unit weight
30 lb
40 lb shipping
Static, intermittent and cyclic modes 100-240 V, 50/60 Hz, 75 VA Variable speed at 30, 50 or 100% Securing bracket in the carton

The head

How it works

The Triton times each phase of the pull on its own and stores the motor speed with the protocol.

Stored protocols
Storage runs to 80 user-defined protocols, room for every clinician's cervical and lumbar settings. Each slot keeps the mode, the tension, the hold and rest times and the progressive and regressive step counts, so setting up a repeat patient is one selection at the console.
80 slots
Pull patterns and pretension
The pull patterns cover gradient, progressive range of motion and oscillations. Programmable pretension runs before traction starts, which gives the acute patient a gentler start.
Pretension
Variable motor speed
The traction motor runs at three speed settings, 30%, 50% and 100%, and the rate at which tension comes on and comes off is a parameter you choose and store with the protocol. Variable speed adds patient comfort and treatment flexibility.
30 / 50 / 100%
A color touch screen
A high contrast color touch screen carries a full color graphic library of anatomical images, common pathologies and a belting technique tutorial, alongside the cervical and lumbar Clinical Protocols. The screen turns through 270 deg, and a clinician standing on either side of the table can read it and drive it without walking around the head end.
Color, 270 deg

Triton in the clinic

Key features

Factory protocols, patient records that travel between visits and an sEMG build widen what a Triton head runs and keeps.

Patient Interrupt Switch
The Patient Interrupt Switch is required for the unit to function, and it stays in the patient's grasp throughout the traction therapy.
Factory Clinical Protocols
Cervical and lumbar Clinical Protocols are loaded at the factory, alongside the slots you fill yourself.
Patient Data Cards
Each patient's treatment sessions and pain records go on a card that comes back with them at the next visit.
An sEMG build
The same head is also built as the Triton Traction Unit with sEMG, with the sEMG module already fitted.

Triton in use

Videos

The range

How it compares

The Triton stores eighty protocols on a color screen and the TX ten on a monochrome one. The Traction Kit pairs a TX with belting, a Saunders cervical device and a flexion stool.

Chattanooga TX Traction Unit traction head
TX Traction Unit
Monochrome touch screen, 10 stored protocols, Patient Data Cards holding 14 sessions.
0 to 200 lb (0 to 90 kg / 0 to 890 N) High contrast monochrome touch screen Up to 10 user-defined treatment protocols Patient Data Cards: up to 14 treatment sessions
Shop the TX Traction Unit
You're Here
Chattanooga Triton Traction Unit traction head
Triton Traction Unit
Color touch screen, 80 stored protocols, variable speed motor, and an sEMG option.
0 lb to 200 lb (0 to 90 kg / 0 to 890 N) High contrast color touch screen Up to 80 user-defined protocols Variable speed motor: 30%, 50%, 100%
Currently viewing
Chattanooga TX Traction Kit, traction head, belt, stool and cervical device
Traction Kit
The TX unit supplied with QuikWrap belt, Saunders cervical device and flexion stool.
0 to 200 lb (0 to 90 kg / 0 to 890 N) Up to 10 user-defined treatment protocols 14 treatment sessions per card; 5 cards supplied QuikWrap belt for pelvic or lumbar traction up to 300 lb
Shop the Traction Kit

Questions

Frequently asked questions

Off a load cell in the head, so the figure on the screen is the figure on the cord, in 1 lb increments up to 890 N. Static, intermittent and cyclic modes can also be combined.

A traction table and a belt set, at minimum. The head mounts on its securing bracket to a Triton 6M, a Triton 6E, a Galaxy TTET-300 or a Galaxy TTET-400, all sold separately. Lumbar and pelvic belting is the QuikWrap DTS Belt System or the Deluxe Universal Belt System, and cervical work runs through the Saunders Clinical Cervical Traction System, which arrives with its own clevis. A Traction Flexion Stool and a Knee Bolster Set cover positioning.

The Triton Patient Interrupt Switch, part 48083. Test its cable before each use.

The carton holds the Triton Traction Unit, Patient Data Cards (5), Securing Bracket, Patient Interrupt Switch (9 ft / 2.75 m, shielded, 26 AWG), Patient Interrupt Switch Hook Kit, Mains Power Cord (80 in. / 203 cm, shielded, 18 AWG) and the User Manual. The two sEMG builds add an sEMG lead wire and two sets of four Dura-Stick II electrodes. Belting, bolsters, the flexion stool and the cervical traction device are all ordered on their own.

100 V to 240 V at 50/60 Hz, drawing 75 VA and 3.2 A max. It is Class I, Type B, rated for continuous operation. The head measures 9.5 x 17.5 x 17.5 in. (24 x 45 x 45 cm) on its bracket.

One year (12 months) from original consumer purchase on the unit and 90 days on the accessories shipped with it, which covers the Patient Interrupt Switch, the hook kit, the securing bracket and the mains cord in the carton. Annual factory calibration is required for Triton traction units, and service should be performed only by a Field Service Technician certified by Chattanooga Group. Inspect the traction cord for wear before each use; the replacement cord is part 48031.

Traction is contraindicated where any of the following are present: structural disease secondary to tumor or infection; vascular compromise; any condition where movement is contraindicated; acute strains, sprains, inflammation aggravated by traction; joint instability of the spine; pregnancy; osteoporosis; hiatus hernia; claustrophobia; cardiac or pulmonary problems. A clinician experienced with traction has to be familiar with the user manual before administering traction, and each patient should be individually assessed to determine the appropriateness of the parameter settings prior to use.

Five cards ship in the carton. A card stores treatment sessions, pre- and post-treatment pain scales, pain mapping and pain types, and the record travels with the patient between visits without anyone re-keying it.

They apply to the two sEMG builds and to the sEMG module itself, and they do not describe the base head. The module is 6.63 x 3 x 1.63 in. (16.83 x 7.62 x 4.13 cm) at 5.2 oz (146 g), with input impedance above 1,000,000 ohm, input sensitivity below 1.0 microvolt RMS, and a frequency range of 15 Hz to 1000 Hz with CMRR above 120 dB (above 180 dB at 50/60 Hz). The sEMG input is Type BF where the rest of the unit is Type B.

  • Model: 4739
  • Traction tension range: 0 to 200 lb (0 to 90 kg / 0 to 890 N)
  • Tension increment: 1 lb (1 kg / 5 N)
  • Traction period: 1 to 99 min, 1 min increments
  • Hold period: 0 to 99 sec, 1 sec increments
  • Rest period: 0 to 99 sec, 1 sec increments
  • Progressive steps: 1 to 9 steps
  • Regressive steps: 1 to 9 steps
  • Motor speed settings: 30%, 50%, 100%
  • Dimensions: 9.5 x 17.5 x 17.5 in. (24 x 45 x 45 cm)
  • Weight: 30 lb (14 kg); shipping 40 lb (18 kg)
  • Mains power: 100 V to 240 V, 50/60 Hz, 75 VA, 3.2 A max
  • Electrical class: Class I, Type B; Type BF on the sEMG input
  • Duty cycle: Continuous operation
  • Operating and storage temperature: 0 F to 140 F (-18 C to 60 C)
  • Warranty: 1 year (12 months) on the unit; 90 days on accessories
  • Traction modes: Static, intermittent, cyclic, and combinations
  • Pull patterns: Five: gradient, progressive range of motion, oscillations
  • Phase timing: Independent for pretension, progression, traction and regression
  • Pretension: Programmable, before traction starts
  • Protocol storage: Up to 80 user-defined protocols
  • Display: High contrast color touch screen, 270 deg pivot
  • Graphic library: Anatomical images, pathologies, belting technique tutorial
  • Clinical protocols: Cervical and lumbar, loaded at the factory
  • Data recording: Patient Data Cards, 5 supplied; sessions, pain scales, pain mapping, pain types
  • Patient Interrupt Switch: Required for operation; part 48083, or 48084 with sEMG
  • Mounting: Securing bracket to a traction table or traction pedestal
  • Traction table: Not included
  • Calibration: Annual factory calibration required
  • Operator requirement: Clinician familiar with the user manual before administering traction
  • sEMG option: Models 4778 and 2841, or module 4766
  • Traction unit: Triton Traction Unit
  • Patient Data Cards: Five
  • Securing bracket: For a traction table or pedestal
  • Patient Interrupt Switch: 9 ft (2.75 m), with hook kit
  • Mains power cord: 80 in. (203 cm)
  • Documentation: User manual
  • Traction table: Not included; sold separately
  • Belting and cervical device: Not included; sold separately